Short answer: A 2026 systematic review of five small comparative studies found a signal favoring fractional CO₂ lasers over erbium-based fractional lasers for a defined atrophic acne-scar response threshold. The same review associated CO₂ treatment with more reported pain and longer downtime. Its randomized-only sensitivity analysis did not establish a statistically clear response difference. A buyer should therefore compare the intended patient group, recovery burden and exact technology rather than turn the pooled result into an “always better” claim.
What did the comparison include?
Song and Zhi searched clinical research through April 2026. Their five included studies enrolled 134 people and analyzed 130. The underlying studies were conducted in South Korea, Egypt, Thailand, Germany and Iran, and their final assessments occurred one to six months after treatment. Two compared fractional CO₂ with nonablative erbium-glass systems, while three used ablative Er:YAG comparators. The study designs and treatment schedules varied. Combining those distinct erbium platforms is useful for an overview, but it does not make them interchangeable products.
Four studies supplied data for the primary analysis, which defined clinical response as greater than 50% improvement according to compatible study-specific assessments. The pooled relative risk was 0.69 for an erbium-based system relative to CO₂, with a 95% confidence interval of 0.49 to 0.97. In this calculation, a value below one favored CO₂. However, the analysis restricted to studies with confirmed random allocation produced an estimate of 0.76 with a confidence interval of 0.54 to 1.08, crossing the no-difference value. Individual subgroup estimates also remained uncertain. The full pooled result should not be presented as a firm head-to-head verdict for a particular pair of machines.
Why do pain and downtime matter to buyers?
Four studies contributed pain measurements on a 0–10 scale. The review reported a pooled mean difference of 1.86 points, with higher pain for CO₂ treatment. Two studies had enough data for a downtime comparison; the pooled difference was 3.67 additional days after CO₂, with a 95% confidence interval from 1.90 to 5.44 days. These are study-level averages from limited reports, not a recovery forecast for every patient or treatment setting. A clinic weighing equipment should ask what aftercare, scheduling and patient counseling a service would require, and whether a proposed claim balances possible response against recovery burden.
The review did not find a statistically clear difference in post-inflammatory hyperpigmentation or acneiform events. That is not proof of equal risk: event data were sparse, and the estimates remained imprecise. Skin phototype was also reported inconsistently across the source studies. Buyers should obtain model-specific labeling, safety documentation and clinically relevant evidence rather than rely on the absence of a significant difference in this small pooled dataset.
What does the paper leave open?
The review covers atrophic acne scars, not surgical, burn or other non-acne scars. It compares CO₂ with erbium technologies, not picosecond lasers, IPL, LED or radiofrequency. Different wavelengths, settings, scar subtypes and follow-up times constrain generalization. One included study used a non-randomized fixed-side design; the authors explicitly tested how excluding it affected the response estimate. A clinic should define its exact service and check whether the supplier’s own evidence addresses that same use.
This international evidence review is not a device approval or jurisdiction-specific legal advice for Germany or any other European market. TUOKE’s optical aesthetic equipment insights provide other research interpretation for buyers. The article does not assert that TUOKE sells or has regulatory authorization for either laser type.
Primary source: Song and Zhi, “Comparative efficacy and safety of fractional carbon dioxide and erbium-based fractional lasers for atrophic acne scars: A systematic review and meta-analysis”, Lasers in Medical Science, published 10 September 2026; full article reviewed 27 October 2026.